How do you exchange data via Profibus DP between a Moeller PLC with a CM4-504/LE4-504/PS416-NET-441 and a Siemens S7/C7?
Use Siemens system function SFC13/SFC14/SFC15.
How can you display I/O status information and other modules in the DP Configurator, and how do you force the outputs?
Click on the question to obtain information.
How can you connect a PROFIBUS-DP master and a PROFIBUS-DP slave to the PS4-341-MM1 together?
Click on the question to obtain information.
How much data can a PS416-NET-440 Profibus DP master card send to each station and how much can it receive ?
The PS416-NET-440 can receive 244 bytes and send 244 bytes.
On which PC operating systems does the PROFIBUS-FMS Configurator run ?
From version 3.3 or higher, MS-Windows 95, MS-Windows 98 and MS-Windows NT. Before this version, only MS-Windows 3.xx.
Is there a German version of the Profibus DP Configurator ?
Click on the question to obtain information.
How can consistent data be received with a Profibus DP master?
By adjustment of the consistent data length
What cable can be used for PROFIBUS-DP ?
Click the question to obtain the technical data of the cable.
How can large volumes of data be transferred via Suconet K or PROFIBUS-DP ?
The Suconet K/PROFIBUS-DP data multiplexer application module enables the transfer of large data volumes.
Is there a data multiplexer for Suconet-K / PROFIBUS-DP ?
Yes, the application module S40-AM-K1-GB contents a data multiplexer for Suconet-K / PROFIBUS-DP.
Which PS4 type can be equipped with the PROFIBUS-DP master module ?
Only the PS4-341-MM1.
How is the current version of the Profibus-DP Configurator for S40 available ?
Over download, please click on the question.
Are the LE4-504-BT1 and PS416-NET441 PROFIBUS-DP slave modules certified by the Profibus User Organisation (PNO) and the Underwriter Laboratories (UL) ?
Yes
What is the maximum number of slave stations that can be run with the
LE4-504-BS1 (PROFIBUS-DP master) ?
124 Slaves
What design measures are required to integrate an LE4-504-BT1 (PROFIBUS-DP Slave) in a STEP 7 hardware configuration?
The design measures for integrating an LE4-504-BT1 (PROFIBUS-DP Slave) in a STEP 7 hardware configuration are shown in a video that can be downloaded.
How can an MV4 touch panel be connected to a Siemens S7 PLC?
An MV4 touch panel can be connected to a Siemens S7 PLC using PROFIBUS-DP.
How can PS4/PS416 systems be networked with PROFIBUS-FMS?
Different modules/cards are available for networking PS4/PS416 systems with PROFIBUS-FMS. Click the question to obtain further information.
How can the PS416 networked with PROFIBUS-PA?
The PS416 can be networked with PROFIBUS-PA using a segment coupler.
Is there a software to support the PROFIBUS-DP link of the Easy control relay to the EASY204-DP module with a MOELLER control system PS4 / PS416 ?
The S40-AM-K6-D/GB application module is provided for this purpose. Click the question to obtain the application module via the Internet.
Is there a software to support the PROFIBUS-DP link of the Easy control relay with the EASY204-DP module to the Siemens S7-300 ?
The S7-AM-K6-D/GB application module is provided for this purpose.
Can DF5 and DV5 series frequency inverters be connected to PROFIBUS-DP?
Yes